< Metal sheet preparation - Tooling - Setting >
|
Metal sheet preparation according to shape
Body |
|
|
Ø 4.8 |
Ø 6.4 |
 |
Standard |
|
4.9 / 5.1 |
6.6 / 7.0 |
|
|
|
|
|
< Metal sheet preparation - Tooling - Setting >
|
Installation tooling
BOLTOFIX™ should be installed using the TFR104 or TFR107 oleopneumatic riveting tool or the TFR304 manual riveting tool, available in the TOOLIN'FIX™ section. Use of a standard tool matching the selected BOLTOFIX™ diameter is imperative to carrying out installation. |
|
 |
| Riveting tool |
Nozzle |
BOLTOFIX™ |
|
|
|
BOLTOFIX™ installation process |
|
|
|
For more details about all tools, please refer to the TOOLIN'FIX™ data sheets.
|
|
|
< Metal sheet preparation - Tooling - Setting >
|
BOLTOFIX™ installation settings
To ensure optimal installation of BOLTOFIX™, the correct level of pressure supply to the equipment is essential. |
|
 |
|
Air Pressure
This parameter concerns only oleopneumatic tools.
The air supply pressure level determines the setting force of the installation tool.
The minimum pressure required is 6 bars. This value corresponds to the usual pressure of an air pressure supply network.
To guarantee optimum riveting, it is advise to use an air pressure gauge between the air supply and installation tool.
|
|
|
|
|